Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Res Cardiol ; 110(2): 220-227, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32876814

RESUMO

OBJECTIVES: We aimed to investigate long-term survival of paclitaxel DCB for percutaneous coronary intervention (PCI). BACKGROUND: Safety concerns have been raised over the use of paclitaxel devices for peripheral artery disease recently, following a meta-analysis suggesting increased late mortality. With regard to drug-coated balloon (DCB) angioplasty for coronary artery intervention however, there is limited data to date regarding possible late mortality relating to paclitaxel. METHODS: We compared all-cause mortality of patients treated with paclitaxel DCB to those with non-paclitaxel second-generation drug-eluting stents (DES) for stable, de novo coronary artery disease from 1st January 2011 till 31st December 2018. To have homogenous groups allowing data on safety to be interpreted accurately, we excluded patients with previous PCI and patients treated with a combination of both DCB and DES in subsequent PCIs. Data were analysed with Kaplan-Meier curves and Cox regression statistical models. RESULTS: We present 1517 patients; 429 treated with paclitaxel DCB and 1088 treated with DES. On univariate analysis, age, hypercholesterolaemia, hypertension, peripheral vascular disease, prior myocardial infarction, heart failure, smoking, atrial fibrillation, decreasing estimated glomerular filtration rate (eGFR) [and renal failure (eGFR < 45)] were associated with worse survival. DCB intervention showed a non-significant trend towards better prognosis compared to DES (p = 0.08). On multivariable analysis age, decreasing eGFR and smoking associated with worse prognosis. CONCLUSION: We found no evidence of late mortality associated with DCB angioplasty compared with non-paclitaxel second-generation DES in up to 5 years follow-up. DCB is a safe option for the treatment of de novo coronary artery disease.


Assuntos
Angioplastia Coronária com Balão/métodos , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Stents Farmacológicos , Paclitaxel/farmacologia , Idoso , Causas de Morte/tendências , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Fatores de Tempo , Resultado do Tratamento , Reino Unido/epidemiologia
2.
Int J Cardiol ; 137(3): e47-8, 2009 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-19410310

RESUMO

We report the case of a 64 year old man with two vessel coronary artery disease and a left main coronary artery to pulmonary artery fistula. He underwent coronary artery bypass grafting, but the coronary artery fistula was not closed. He developed recurrent angina due to coronary steal from the distal left anterior descending artery by the maturing coronary artery fistula. This was closed percutaneously by stenting the left main coronary artery with covered stents. The clinical implications and potential mechanisms of the coronary steal due to the coronary artery fistula are discussed.


Assuntos
Angina Pectoris/cirurgia , Fístula Artério-Arterial/cirurgia , Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Angina Pectoris/diagnóstico , Angina Pectoris/etiologia , Angioplastia com Balão , Fístula Artério-Arterial/complicações , Fístula Artério-Arterial/diagnóstico , Cateterismo Cardíaco , Angiografia Coronária , Doença das Coronárias/complicações , Doença das Coronárias/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/cirurgia , Veia Safena/transplante , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA